Breath Ammonia Biomarker Predicts Kidney Function in CKD Patients

By LabMedica International staff writers
Posted on 18 Nov 2020
Print article
Image: The Ammonia Breath test: the sensing system included a desiccation cylinder, an airtight sensing chamber, a rotameter, a pump, and an electrical signal measurement instrument (Photo courtesy of Chang Gung University).
Image: The Ammonia Breath test: the sensing system included a desiccation cylinder, an airtight sensing chamber, a rotameter, a pump, and an electrical signal measurement instrument (Photo courtesy of Chang Gung University).
Chronic kidney disease (CKD) is a type of kidney disease in which there is gradual loss of kidney function over a period of months to years. Initially there are generally no symptoms; later, symptoms may include leg swelling, feeling tired, vomiting, loss of appetite, and confusion.

Diagnosis of CKD is largely based on history, examination and urine dipstick combined with the measurement of the serum creatinine level. It is important to differentiate CKD from acute kidney injury (AKI) because AKI can be reversible. One diagnostic clue that helps differentiate CKD from AKI is a gradual rise in serum creatinine (over several months or years) as opposed to a sudden increase in the serum creatinine (several days to weeks).

Nephrologists at the Chang Gung Kidney Research Center (Taoyan, Taiwan) and their colleagues investigated whether exhaled breath ammonia measurement could be used for rapid CKD screening. The scientists enrolled 121 patients with CKD stages 1 to 5 (average age, 61 years; 62 patients were men) and compared breath ammonia level measurements with blood urea nitrogen (BUN), creatine and eGFR levels. The gas measurement system used in this study was composed of a rotameter, pump, desiccation cylinder, the sensing chamber, and an electrical signal measurement instrument (Keysight Technologies, Santa Rosa, CA, USA).

The team reported that breath ammonia level correlated with BUN, serum creatinine, eGFR and inversed eGFR levels. Breath ammonia concentration was increasingly elevated at each stage of CKD (stage 1: 636 ± 94 ppb; stage 2: 1,020 ± 326 ppb; stage 3: 1,943 ± 326 ppb; stage 4: 4,421 ± 1,042 ppb; stage 5: 12,781 ± 1,807 ppb). The area under curve for a breath ammonia level cutoff concentration of 1,187 ppb comparing patients with eGFR of at least 60 mL/min/1.73 m2 with patients with eGFR of no more than 60 mL/min/1.73 m2 was 0.831 (positive predictive value, 0.84; negative predictive value, 0.61; sensitivity, 71%; specificity, 78%).

The scientists noted that at 886 ppb, the sensitivity increased to 80%, but the specificity decreased to 69%. They also wrote there were no significant differences between patients in each stage regarding sex, body weight, hemoglobin, albumin, comorbidities and medication and that BUN level, creatinine and eGFR increased with each CKD stage.

Ya-chung Tian, MD, an associate professor of nephrology and a co-author of the study, said, “Because CKD is non-life threating and breath ammonia detection was conducted in real time, inexpensive, easy to administer and had an acceptable diagnostic accuracy, breath ammonia can be used as a good surrogate for kidney function and a reliable tool for CKD screening.”

The authors concluded that breath ammonia detection with vertical-channel organic semiconductor (V-OSC) is a real time, inexpensive, and easy to administer measurement device for screening CKD with reliable diagnostic accuracy. The study was published on October 31, 2020 in the journal Biomedical Materials and Nanomedicine.

Related Links:
Chang Gung Kidney Research Center
Keysight Technologies


New
Gold Member
C-Reactive Protein Reagent
CRP Ultra Wide Range Reagent Kit
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
PSA Test
Human Semen Rapid Test
New
Histamine ELISA
Histamine ELISA

Print article

Channels

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.