We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Fidget Spinner Rapidly Detects Urinary Tract Infections

By LabMedica International staff writers
Posted on 16 Jun 2020
Print article
Image: A fidget spinner for the point-of-care diagnosis of urinary tract infection (Photo courtesy of Ulsan National Institute of Science and Technology).
Image: A fidget spinner for the point-of-care diagnosis of urinary tract infection (Photo courtesy of Ulsan National Institute of Science and Technology).
More than half of all women experience at least one episode of urinary tract infection (UTI) in their lifetime, with men also facing increasing risks of infection as they age. Current detection of UTIs relies on patients reporting symptoms followed by a laboratory culture of the urine for known bacterial culprits, which typically takes a few days.

Doctors tend to prescribe antibiotics to suppress any suspect cases of UTI before they get the test results, contributing to the increasing problem of antibiotic resistance. Dipstick tests that reduce the time taken for diagnoses come with a high chance for false positives. The point-of-care detection of pathogens in biological samples in resource-limited settings should be inexpensive, rapid, portable, simple and accurate.

A multidisciplinary and international team of scientists led by the Ulsan National Institute of Science and Technology (Ulsan, Republic of Korea) developed a fidget spinner-based device to detect UTIs from urine samples. The device was field tested on 39 patients in Tiruchirappalli, India who would have all been given antibiotics based on their symptoms alone. The team reported 59% of the patients were found to be over/under-treated with antibiotics, something that can be rectified using this novel device.

The custom-made fidget spinner rapidly concentrates pathogens in 1-mL samples of undiluted urine by more than 100-fold for the on-device colorimetric detection of bacterial load and pathogen identification. The test of the rectangular device with one or two nudges spins for a long time pushing any bacteria onto a membrane. This is then dyed, with a color change visible to the naked eye in less than one hour, which indicates the amount of bacterial load.

The device enabled the on-site detection of infection with the naked eye within 50 minutes in urine samples from the patients suspected of having a urinary tract infection. The team also showed that, in 30 clinical samples of urinary tract infection, the device can be used to perform an antimicrobial susceptibility test for the antimicrobial drugs ciprofloxacin and cefazolin within 120 minutes.

Another test gave a preliminary indication of the presence of antibiotic resistance. By testing the spun samples treated with different drugs and comparing them to untreated samples, the team was able to quickly make a decision on which antibiotic might work best to treat the UTI. While this does not compare to laboratory based tests for microbial resistance, it is still a useful add-on for resource poor settings that do not typically test for resistance.

The authors concluded that the test can be performed by novices and that there is no extensive training that is required to learn how to spin the device and read the results. The ease-of-use, low price point, availability of quick results, and immediate benefits such as reduction in prescription of antibiotics, makes the new spinner an attractive alternative for diagnosing UTIs. The study was published on May 18, 2020 in the journal Nature Biomedical Engineering.

Related Links:
Ulsan National Institute of Science and Technology

Gold Member
Blood Gas Analyzer
GEM Premier 7000 with iQM3
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Lab Sample Rotator
H5600 Revolver
New
17 Beta-Estradiol Assay
17 Beta-Estradiol Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.