We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

altona Diagnostics GmbH

altona Diagnostics GmbH develops and commercializes real-time PCR based assays and molecular diagnostic test solution... read more Featured Products: More products

Download Mobile App




Prolonged Maternal Zika Viremia Evaluated for Adverse Perinatal Outcomes

By LabMedica International staff writers
Posted on 10 Feb 2021
Print article
Image: The RealStar Zika Virus RT-PCR Kit 1.0 is an in vitro diagnostic test, based on real-time PCR technology, for the qualitative detection of Zika virus specific RNA in human serum or urine (Photo courtesy of Altona Diagnostics).
Image: The RealStar Zika Virus RT-PCR Kit 1.0 is an in vitro diagnostic test, based on real-time PCR technology, for the qualitative detection of Zika virus specific RNA in human serum or urine (Photo courtesy of Altona Diagnostics).
The recent worldwide epidemic confirmed maternal–fetal transmission of Zika virus (ZIKV) and its association with adverse perinatal outcomes, particularly severe central nervous system lesions and fetal losses.

ZIKV is detectable in maternal blood by reverse transcription polymerase chain reaction (RT-PCR) during the acute phase of infection. ZIKV viremia usually lasts from two days before to 16 days after symptom onset. The median time of ZIKV RNA clearance is five days.

A team of medical scientists led by those at Lausanne University Hospital (Lausanne, Switzerland) carried out a prospective cohort study in French Guiana and enrolled Zika virus–infected pregnant women with a positive PCR result at inclusion and non-infected pregnant women; both groups underwent serologic testing in each trimester and at delivery during January–July 2016. Prolonged viremia was defined as ongoing virus detection >30 days post-infection.

The team performed molecular and serologic testing using the RealStar Zika Kit (Altona Diagnostics GmbH, Hamburg, Germany) for RT-PCR, in-house IgM and IgG antibody-capture ELISA, and microneutralization assays for serologic testing. The limit of detection for serum samples tested using the RealStar Zika Kit was 0.61 copies/μL (95% CI 0.39–1.27). A cycle threshold (Ct) value <37 was considered positive.

The team reported that adverse outcomes (fetal loss or neurologic anomalies) were more common in fetuses and neonates from mothers with prolonged viremia (40.0%) compared with those from infected mothers without prolonged viremia (5.3%, adjusted relative risk [aRR] 7.2 [95% CI 0.9–57.6]) or those from non-infected mothers (6.6%, aRR 6.7 [95% CI 3.0–15.1]). Congenital infections were confirmed more frequently in fetuses from mothers with prolonged viremia (9/15 [60.0%]) when compared with those from infected mothers without prolonged viremia (5/19 [26.3%], RR 2.3 [95% CI 1.0–5.4]) and non-infected mothers (0/332 [0.0%]).

The authors concluded that prolonged maternal ZIKV viremia could be a marker for an increased risk for maternal–fetal transmission and subsequent adverse perinatal outcomes. Even if prolonged maternal viremia is not consistently present in cases of congenital infection, it might reflect active viral replication in the fetal–placental compartment and should lead to an enhanced prenatal and neonatal follow-up. The study was published in the February 2021 issue of the journal Emerging Infectious Diseases.

Related Links:
Lausanne University Hospital
Altona Diagnostics GmbH


New
Gold Member
Rotavirus Test
Rotavirus Test - 30003 – 30073
New
Gold Member
LEISHMANIA Test
LEISHMANIA ELISA
New
Crypto + Giardia One Step Combo Card Test
CerTest Crypto + Giardia
New
Gold Member
Legionella Pneumophila Test
Legionella Pneumophila ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: A coronal MRI section shows a high-intensity focused ultrasound lesion in the left thalamus of the brain (Photo courtesy of UT Southwestern Medical Center)

Newly Identified Stroke Biomarkers Pave Way for Blood Tests to Quickly Diagnose Brain Injuries

Each year, nearly 800,000 individuals in the U.S. experience a stroke, which occurs when blood flow to specific areas of the brain is insufficient, causing brain cells to die due to a lack of oxygen.... Read more

Immunology

view channel
Image: The discovery of biomarkers could improve endometrial cancer treatment (Photo courtesy of Mount Sinai)

Simple Blood Test Could Help Choose Better Treatments for Patients with Recurrent Endometrial Cancer

Endometrial cancer, which develops in the lining of the uterus, is the most prevalent gynecologic cancer in the United States, affecting over 66,000 women annually. Projections indicate that in 2025, around... Read more

Pathology

view channel
Image: As tumor cells flow through these microfluidic chambers, they are subjected to increasing shear stress and sorted based on their adhesion strength (Photo courtesy of UC San Diego)

Microfluidic Device Assesses Stickiness of Tumor Cells to Predict Cancer Spread

Ductal carcinoma in situ (DCIS), a type of early-stage breast cancer, is often referred to as stage zero breast cancer. In many cases, it remains harmless and does not spread beyond the milk ducts where... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.