We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

altona Diagnostics GmbH

altona Diagnostics GmbH develops and commercializes real-time PCR based assays and molecular diagnostic test solution... read more Featured Products: More products

Download Mobile App




Prolonged Maternal Zika Viremia Evaluated for Adverse Perinatal Outcomes

By LabMedica International staff writers
Posted on 10 Feb 2021
Print article
Image: The RealStar Zika Virus RT-PCR Kit 1.0 is an in vitro diagnostic test, based on real-time PCR technology, for the qualitative detection of Zika virus specific RNA in human serum or urine (Photo courtesy of Altona Diagnostics).
Image: The RealStar Zika Virus RT-PCR Kit 1.0 is an in vitro diagnostic test, based on real-time PCR technology, for the qualitative detection of Zika virus specific RNA in human serum or urine (Photo courtesy of Altona Diagnostics).
The recent worldwide epidemic confirmed maternal–fetal transmission of Zika virus (ZIKV) and its association with adverse perinatal outcomes, particularly severe central nervous system lesions and fetal losses.

ZIKV is detectable in maternal blood by reverse transcription polymerase chain reaction (RT-PCR) during the acute phase of infection. ZIKV viremia usually lasts from two days before to 16 days after symptom onset. The median time of ZIKV RNA clearance is five days.

A team of medical scientists led by those at Lausanne University Hospital (Lausanne, Switzerland) carried out a prospective cohort study in French Guiana and enrolled Zika virus–infected pregnant women with a positive PCR result at inclusion and non-infected pregnant women; both groups underwent serologic testing in each trimester and at delivery during January–July 2016. Prolonged viremia was defined as ongoing virus detection >30 days post-infection.

The team performed molecular and serologic testing using the RealStar Zika Kit (Altona Diagnostics GmbH, Hamburg, Germany) for RT-PCR, in-house IgM and IgG antibody-capture ELISA, and microneutralization assays for serologic testing. The limit of detection for serum samples tested using the RealStar Zika Kit was 0.61 copies/μL (95% CI 0.39–1.27). A cycle threshold (Ct) value <37 was considered positive.

The team reported that adverse outcomes (fetal loss or neurologic anomalies) were more common in fetuses and neonates from mothers with prolonged viremia (40.0%) compared with those from infected mothers without prolonged viremia (5.3%, adjusted relative risk [aRR] 7.2 [95% CI 0.9–57.6]) or those from non-infected mothers (6.6%, aRR 6.7 [95% CI 3.0–15.1]). Congenital infections were confirmed more frequently in fetuses from mothers with prolonged viremia (9/15 [60.0%]) when compared with those from infected mothers without prolonged viremia (5/19 [26.3%], RR 2.3 [95% CI 1.0–5.4]) and non-infected mothers (0/332 [0.0%]).

The authors concluded that prolonged maternal ZIKV viremia could be a marker for an increased risk for maternal–fetal transmission and subsequent adverse perinatal outcomes. Even if prolonged maternal viremia is not consistently present in cases of congenital infection, it might reflect active viral replication in the fetal–placental compartment and should lead to an enhanced prenatal and neonatal follow-up. The study was published in the February 2021 issue of the journal Emerging Infectious Diseases.

Related Links:
Lausanne University Hospital
Altona Diagnostics GmbH


New
Gold Member
C-Reactive Protein Reagent
CRP Ultra Wide Range Reagent Kit
Automated Blood Typing System
IH-500 NEXT
New
Vitamin B12 Test
CHORUS CLIA VIT B12
New
Newborn Screening Test
NeoMass AAAC 3.0

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.