Novel Device Reduces Blood Draw Contamination

By LabMedica International staff writers
Posted on 01 Jun 2017
Print article
Image: The SteriPath initial specimen diversion device reduces blood culture contamination (Photo courtesy of Magnolia Medical Devices).
Image: The SteriPath initial specimen diversion device reduces blood culture contamination (Photo courtesy of Magnolia Medical Devices).
A novel device can significantly reduce contamination of blood cultures, potentially reducing risky overtreatment and unnecessary use of antibiotics for many patients. This approach could also substantially reduce healthcare costs.

Thousands of patients get their blood drawn every day for blood cultures in order to diagnose serious infections such as sepsis, which can be a deadly condition. A small but significant percentage of the blood cultures are contaminated, due in part to skin fragments containing bacteria that are dislodged during a blood draw.

Scientists at the University of Nebraska Medical Center conducted a prospective, controlled study with 904 patients and 1,808 blood cultures and compared the standard procedure to an initial specimen diversion device (ISDD) to determine whether blood culture contamination was reduced. The sterile blood collection system diverts and sequesters the first 1.5 to 2 mL of blood, which often carries contaminating skin cells and microbes and this part of the blood is discarded.

The team used the SteriPath initial specimen diversion device and were able to decrease the false positive rate significantly through use of this device, from 1.78% down to 0.2%, which represents an 88% reduction. Contamination rates routinely range from 0.6% to 6% in health care institutions the USA. Costs associated with blood culture contamination per patient case ranged from USD 1,000 in 1998 to USD 8,700 in 2009. A more recent study in the USA observed excess charges of USD 8,720 per contamination event.

Mark Rupp, MD, professor and lead author of the study, said, “A lot of people think this is a minor problem. However, contaminated blood cultures are a big deal. Physicians can be led astray and patients may be harmed by additional tests and unnecessary antimicrobial therapy. What is important about this device is it can greatly limit the blood culture from being contaminated, so physicians are rarely fooled by false-positive results. It gives clinicians confidence that results are accurate.” The study was published on in the journal Clinical Infectious Diseases.

Gold Member
Serological Pipet Controller
PIPETBOY GENIUS
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Coagulation Analyzer
CS-2400
New
Total 25-Hydroxyvitamin D₂ & D₃ Assay
Total 25-Hydroxyvitamin D₂ & D₃ Assay

Print article

Channels

Molecular Diagnostics

view channel
Image: Researcher Kanta Horie places a sample in a mass spectrometer that measures protein levels in blood plasma and other fluids (Photo courtesy of WashU Medicine)

Highly Accurate Blood Test Diagnoses Alzheimer’s and Measures Dementia Progression

Several blood tests are currently available to assist doctors in diagnosing Alzheimer's disease in individuals experiencing cognitive symptoms. However, these tests do not provide insights into the clinical... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.