Viral DNA Extracted from Histology Specimens

By LabMedica International staff writers
Posted on 02 Aug 2011
Print article
DNA from archived formalin-fixed, paraffin-embedded (FFPE) tissues can be used for papillomavirus genotyping, but there are potential problems.

These problems for genotyping of the Human papillomavirus (HPV), include paraffin as a physical barrier, DNA cross-linking, and inhibitors of the polymerase chain reaction (PCR).

Investigators at the US Centers for Disease Control and Prevention (CDC; Atlanta, GA, USA) extracted DNA from 10-μm sections from 150 FFPE cancer samples. They combined a commercially available DNA isolation kit, the DNeasy blood and tissue kit, with a heat treatment and evaluated the resulting DNA with regards to HPV typing. Paraffin was removed by xylene and tissue lysed at 56 °C. A second section was directly incubated at 120 °C and subsequently lysed at 65 °C. After spin-column purification, both extracts were tested with a linear array HPV genotyping assay. Cellular DNA yield, HPV16 DNA copies, and PCR inhibitors were assessed by quantitative real-time PCR (qPCR) assays.

Inadequate linear array HPV genotyping assay results were significantly more frequent in xylene-treated than in heat-treated extracts. HPV detection also differed, with 94/150 (62.7%) positives in the xylene treated and 110/150 (73.3%) positive results in the heat-treated extracts. The heat method also yielded 8.2-fold more PCR-amplifiable cellular DNA and 6.5-fold more HPV16 copies, although PCR inhibitors also had a greater effect.

The DNeasy blood and tissue kit used in the study is a product of Qiagen (Valencia, CA, USA) and some improvements may be due to the increased heat during the proteinase K treatment in the kit, which was previously found more effective for tissue lysis. The improvement might also be due to reversal of formaldehyde-induced cross-linking of nucleic acids through the 120 °C incubation. All qPCR assays were performed in a C1000 thermal cycler with a CFX96 real-time system (Bio-Rad; Hercules, CA, USA). The authors concluded that aggressive heat treatment demonstrated an advantage over traditional xylene purification protocols, resulting in higher DNA yields and increased sensitivity for HPV testing. The study was published on July 4, 2011, in the Journal of Molecular Diagnostics.

Related Links:

US Centers for Disease Control and Prevention
Qiagen


Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test
Unit-Dose Packaging solution
HLX
New
Hemacytometer Cover Glasses
Propper Hemacytometer Cover Glasses
New
Clinical Sample Concentrator
QIAamp DSP Virus Kit

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The discovery of a new blood group has solved a 50- year-old mystery (Photo courtesy of 123RF)

Newly Discovered Blood Group System to Help Identify and Treat Rare Patients

The AnWj blood group antigen, a surface marker discovered in 1972, has remained a mystery regarding its genetic origin—until now. The most common cause of being AnWj-negative is linked to hematological... Read more

Microbiology

view channel
Image: The inbiome molecular culture ID technology has received FDA breakthrough device designation (Photo courtesy of inbiome)

Revolutionary Molecular Culture ID Technology to Transform Bacterial Diagnostics

Bacterial infections pose a major threat to public health, contributing to one in five deaths worldwide. Current diagnostic methods often take several days to provide results, which can delay appropriate... Read more

Pathology

view channel
Image: Confocal- & laminar flow-based detection scheme of intact virus particles, one at a time (Photo courtesy of Paz Drori)

Breakthrough Virus Detection Technology Combines Confocal Fluorescence Microscopy with Microfluidic Laminar Flow

Current virus detection often relies on polymerase chain reaction (PCR), which, while highly accurate, can be slow, labor-intensive, and requires specialized lab equipment. Antigen-based tests provide... Read more

Industry

view channel
Image: The GeneXpert system’s fast PCR Xpert tests can fight AMR and superbugs with fast and accurate PCR in one hour (Photo courtesy of Cepheid)

Cepheid Partners with Fleming Initiative to Fight Antimicrobial Resistance

Antimicrobial resistance (AMR) is responsible for over one million deaths globally each year and poses a growing challenge in treating major infectious diseases like tuberculosis, Escherichia coli (E.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.