We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Breath Test Detects Early-Stage Parkinson's Disease

By LabMedica International staff writers
Posted on 15 Aug 2018
Print article
Image: Early diagnosis of Parkinson’s disease is important because it affects the choice of therapy and is subject to a relatively high degree of error (Photo courtesy of Technion - Israel Institute of Technology).
Image: Early diagnosis of Parkinson’s disease is important because it affects the choice of therapy and is subject to a relatively high degree of error (Photo courtesy of Technion - Israel Institute of Technology).
Parkinson's disease (PD) is a degenerative disease that destroys brain tissue and affects movement. It has four main symptoms: stiffness, shaking, slowness, and problems with coordination and balance. Other problems can also develop as the disease progresses, including fatigue, speech difficulties, disrupted sleep, memory problems, and depression.

The disease is complex and diverse and arises differently in different people. However, there are some common features, the main one being the dead dopamine-producing cells in a brain area called the substantia nigra. Dopamine is a brain chemical that carries messages that control movement and other functions. There are around 10 million people living with Parkinson's disease worldwide, including one million in the USA.

Scientists at the Technion - Israel Institute of Technology (Haifa, Israel) described for the first time a clinical trial to distinguish between de novo PD and control subjects using an electronic system for the detection of volatile molecules in exhaled breath (sensor array). They further determined for the first time the association to other common tests for PD diagnostics as smell, ultrasound, and nonmotor symptoms. The test group consisted of 29 PD patients after initial diagnosis by an experienced neurologist, compared with 19 control subjects of similar age who did not have the disease.

The breath-testing device contains an array of 40 sensors made of carbon nanotubes or gold nanoparticles. Each sensor had a different chemical attached that could bind certain volatile molecules in the breath, and this binding changed the electrical resistance of the sensor. The authors reported that the test was able to detect early-stage Parkinson's patients before medication and showed sensitivity, specificity, and accuracy values of the sensor array to detect PD from controls were 79%, 84%, and 81% respectively, in comparison with midbrain ultrasonography (93%, 90%, 92%) and smell detection (62%, 89%, 73%).

The authors concluded that although the device needs to be improved and validated by larger studies, they say that it has potential as a small, portable system to screen at-risk individuals without the need for highly trained specialists. The study was published online on July 10, 2018, in the journal ACS Chemical Neuroscience.

Related Links:
Technion - Israel Institute of Technology

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
One Step HbA1c Measuring System
GREENCARE A1c
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Molecular Diagnostics

view channel
Image: The QIAstat-Dx Analyzer 2.0 with remote test results access enhances collaboration across the healthcare system (Photo courtesy of QIAGEN)

Upgraded Syndromic Testing Analyzer Enables Remote Test Results Access

QIAGEN (Venlo, the Netherlands) has released the QIAstat-Dx Analyzer 2.0, including the Software 1.6 upgrade. This represents a significant advancement from the initial QIAstat-Dx Analyzer 1.... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The RedDrop One blood collection device has received 510(k) clearance from the U.S. FDA for prescription use (Photo courtesy of RedDrop Dx)

Innovative Blood Collection Device Overcomes Common Obstacles Related to Phlebotomy

The discomfort associated with traditional blood draws leads to a significant issue: approximately 30% of diagnostic tests prescribed by physicians are never completed by patients. This avoidance is often... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.