We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Shrink-Wrap Technology Helps Enhance Detection of Biomarkers

By LabMedica International staff writers
Posted on 02 Apr 2014
Print article
Image: Close-up images taken with a scanning electron microscope (SEM) showing the shrink-wrap surface with metal-coating made of a fixed amount of gold (10 nm) and different thicknesses of nickel:  Left: 5 nm thick. Middle: 15 nm thick. Right: 25 nm thick (Photo courtesy of Optical Materials Express).
Image: Close-up images taken with a scanning electron microscope (SEM) showing the shrink-wrap surface with metal-coating made of a fixed amount of gold (10 nm) and different thicknesses of nickel: Left: 5 nm thick. Middle: 15 nm thick. Right: 25 nm thick (Photo courtesy of Optical Materials Express).
Image:  Close-up images of the new metal-coated shrink-wrap nanostructures taken with a scanning electron microscope (SEM). Each image depicts the shrink-wrap surface with metal-coating made of a fixed amount of nickel (5 nm) and different thicknesses of gold:  Top: 10 nm thick. Middle: 20 nm thick. Bottom: 30 nm thick. The black arrows in the top image indicate a nanogap (Photo courtesy of Optical Materials Express).
Image: Close-up images of the new metal-coated shrink-wrap nanostructures taken with a scanning electron microscope (SEM). Each image depicts the shrink-wrap surface with metal-coating made of a fixed amount of nickel (5 nm) and different thicknesses of gold: Top: 10 nm thick. Middle: 20 nm thick. Bottom: 30 nm thick. The black arrows in the top image indicate a nanogap (Photo courtesy of Optical Materials Express).
A novel technique uses wrinkles in metal-coated shrink-wrap to boost fluorescent signals 1,000-fold. The new technology may pave the way for low-cost, highly sensitive biomarker detection and diagnostic devices, and for enabling clinics in resource-limited regions provide their communities with more sensitive detection of infectious diseases.

A persistent challenge in fluorescence detection is to increase the signal to noise ratio of weakly fluorescent biomarkers or of biomolecules present at low concentration. Also, current methods for detection of infectious disease agents are predominantly cost-prohibitive in most areas of the world. Now a novel nanotechnology method using common shrink-wrap may help solve both problems.

The new technology, described by H. Sharma et al. in the Optical Society’s (Washington DC, USA) journal Optical Materials Express, on March 20, 2014, offers a way to significantly boost the signal of fluorescent markers used in biosensing by depositing a combination of metals onto shrink-wrap. “Using commodity shrink-wrap and bulk manufacturing processes, we can make low-cost nanostructures to enable fluorescence enhancements greater than a 1,000-fold, allowing for significantly lower limits of detection,” said Michelle Khine, biomedical engineering professor at the University of California, Irvine (USA); “If you have a solution with very few molecules that you are trying to detect—as in the case of infectious diseases—this platform will help amplify the signal so that a single molecule can be detected.”

In the method, developed by the UC Irvine team led by Prof. Khine, thin layers of gold and nickel are first deposited onto a prestressed thermoplastic polymer (shrink-wrap film). When heated, the shrink-wrap contracts, causing the stiffer metal layers to buckle and wrinkle into flower-like structures that are significantly smaller than previously achieved. Fluorescent-probe tagged biomarkers are added onto the wrinkled metal layer. Specifically, they observed more than three orders of magnitude enhancement in the fluorescence signal emitted from a single molecule of goat anti-mouse immunoglobulin G (IgG) antibody tagged with fluorescein isothiocyanate, FITC, (FITC-IgG), by two-photon excitation.

The enhanced emission is due to the excitation of localized surface plasmons (coherent oscillations of the free electrons in the metal). When light was shined onto the wrinkled surface, the electromagnetic field was amplified within the nanogaps between the shrink-wrap folds. This produced “hotspot” areas characterized by sudden bursts of intense fluorescence signals from the biomarkers. This is the first demonstration of leveraging the plasmons in such hybrid nanostructures by metal enhanced fluorescence (MEF) in the near-infrared wavelengths. The structures can be tuned to have a diverse range of architectures and nanogap sizes with tunable plasmon resonances, to achieve large fluorescence enhancements in other regions of the excitation wavelength spectrum.

Though the current setup requires expensive equipment, the team believes this approach will pave the way to creating an integrated, low-cost device to magnetically trap and sensitively detect labeled molecules and nanoparticles. However, biological sample testing is itself another technical challenge: “The technique should work with measuring fluorescent markers in biological samples, but we have not yet tested bodily fluids,” said Prof. Khine, who cautions that the technique is far from ready for clinical use. For example, she notes, “We are currently working on trying to detect Rotavirus, but one of the main challenges is that our surface is hydrophobic so diffusion of the biomarker onto our composite structures is limited."

University of California, Irvine
The Optical Society

Related Links:
New
Gold Member
Syphilis Screening Test
VDRL Antigen MR
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Silver Member
Apolipoprotein A-I Assay
Apo A-I Assay
New
Automatic Biochemistry Analyzer
Audmax 180 Evolution

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Microbiology

view channel
Image: HNL Dimer can be a novel and potentially useful clinical tool in antibiotic stewardship in sepsis (Photo courtesy of Shutterstock)

Unique Blood Biomarker Shown to Effectively Monitor Sepsis Treatment

Sepsis remains a growing problem across the world, linked to high rates of mortality and morbidity. Timely and accurate diagnosis, along with effective supportive therapy, is essential in reducing sepsis-related... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.