We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Seegene

Seegene, Inc. is a developer of multiplex molecular technologies and multiplex clinical molecular diagnostics for inf... read more Featured Products: More products

Download Mobile App




SARS-CoV-2 RNA Test Assessed Among Recovered COVID-19 Patients

By LabMedica International staff writers
Posted on 25 Nov 2020
Print article
Image: Lung cells infected with coronavirus (Photo courtesy of The Hebrew University of Jerusalem).
Image: Lung cells infected with coronavirus (Photo courtesy of The Hebrew University of Jerusalem).
Some patients who have recovered from coronavirus disease 2019 (COVID-19) with documented negative real-time polymerase chain reaction (RT-PCR) results at the time of recovery have had subsequent positive RT-PCR test results for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2).

In the absence of any symptoms suggestive of new SARS-CoV-2 infection and it is unknown whether such patients are infectious and whether they should be quarantined. Real-time PCR is not a viral culture and does not allow determination of whether the virus is viable and transmissible.

A team of medical scientists associated with the Università Cattolica del Sacro Cuore (Rome, Italy) studied 176 recovered patients with COVID-19 who were admitted to the post-acute outpatient service of their institution from April 21 to June 18, 2020, for COVID-19 follow-up. Before that, patients had discontinued isolation according to current criteria which require no fever for three consecutive days, improvement in other symptoms, and two negative RT-PCR results for SARS-CoV-2 RNA 24 hours apart.

Nasal/oropharyngeal swab (NOS) samples from patients at follow-up were analyzed for total (genomic) and replicative (subgenomic) SARS-CoV-2 RNA using RT-PCR assays. Total SARS-CoV-2 RNA Detection and Quantification Total viral RNA was extracted from NOS samples using the Nimbus automated system (Seegene, Seoul, South Korea) which uses STARMag Universal Cartridge kit for both RNA extraction and PCR assay setup.

The RT-PCR testing was performed using the Seegene Allplex 2019-nCoV assay, a single-tube assay targeting three viral genes (E, RdRP, and N). Total viral RNA quantification was performed using the Quanty COVID-19 assay (Clonit S.r.l, Milan, Italy). Serum samples were tested with a commercial assay (Euroimmun; Lübeck, Germany), an enzyme-linked immunosorbent assay (ELISA) that uses the recombinant S1 domain of the SARS-CoV-2 spike (S) protein as antigen, for semi-quantitative detection of anti–SARS-CoV-2 IgG and IgA antibodies.

The investigators reported that 32 of 176 NOS samples (18.2%) tested positive for total SARS-CoV-2 RNA, with viral loads ranging from 1.6 × 101 to 1.3 × 104 SARS-CoV-2 RNA copies per mL. One of the 32 samples (3.1%) had replicative SARS-CoV-2 RNA. Samples from the 32 patients at the time of COVID-19 diagnosis were also tested and, expectedly, had replicative SARS-CoV-2 RNA. All but 1 of 32 patients had a positive serology result against SARS-CoV-2, as well as 139 of remaining 144 patients, at COVID-19 follow-up. The patient who tested serologically negative was not the one with a positive test result for replicative SARS-CoV-2 RNA. The mean ±SD time from COVID-19 diagnosis to follow-up was 48.6 ± 13.1 days in 32 patients and 57.7 ±16.9 days in 144 patients.

The authors concluded that their study highlights that many patients who recovered from COVID-19 may be still positive (albeit at lower levels) for SARS-CoV-2 RNA, but only a minority of the patients may carry a replicating SARS-CoV-2 in the respiratory tract. The study was published on November 12, 2020 in the journal JAMA Internal Medicine.

Related Links:
Università Cattolica del Sacro Cuore
Seegene
Clonit
Euroimmun

Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test
Automated Blood Typing System
IH-500 NEXT
New
Automated Nucleic Acid Extractor
eLab
New
Silver Member
Static Concentrator
BJP 10

Print article

Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Molecular Diagnostics

view channel
Image: Small molecule modulation of protein corona significantly enhances deep plasma proteome profiling (Photo courtesy of Mahmoudi Group)

Smarter Blood Tests Deliver Faster Diagnoses and Improved Outcomes

It has long been established that the earlier a disease is detected, the better the chances for a positive patient outcome. A novel method now offers an in-depth analysis of proteins in plasma, uncovering... Read more

Hematology

view channel
Image: The smartphone technology measures blood hemoglobin levels from a digital photo of the inner eyelid (Photo courtesy of Purdue University)

First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC

Blood hemoglobin tests are among the most frequently conducted blood tests, as hemoglobin levels can provide vital insights into various health conditions. However, traditional tests are often underutilized... Read more

Immunology

view channel
Image: Under a microscope, DNA repair is visible as bright green spots (“foci”) in the blue-stained cell DNA. Orange highlights actively growing cancer cells (Photo courtesy of WEHI)

Simple Blood Test Could Detect Drug Resistance in Ovarian Cancer Patients

Every year, hundreds of thousands of women across the world are diagnosed with ovarian and breast cancer. PARP inhibitors (PARPi) therapy has been a major advancement in treating these cancers, particularly... Read more

Pathology

view channel
Image: Photoacoustic images of a splayed vessel structure underlying very light and dark skin tones (Photo courtesy of asquinha, Gubbi, and Bell, doi 10.1117/1.BIOS.2.1.012502)

New Imaging Technique Reduces Skin Tone Bias in Breast Cancer Detection

Breast cancer remains a significant global health issue, and early detection is key to successful treatment. Traditional imaging techniques like mammography often face challenges, particularly for women... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.